The three pressure valves: (1) relief valve — parallel to the pump outlet, sets the system maximum pressure, relieves / stabilizes pressure / protects safety, normally open or normally closed; (2) reducing valve — in series in a branch, reduces the branch pressure below the main line and stabilizes it, constant outlet pressure, normally open; (3) sequence valve — uses a pressure signal to control the action sequence of actuators (e.g. clamp first then feed), can be internally or externally controlled. Easily confused: relief valve protects the pressure source, reducing valve protects the branch, sequence valve manages the order. An externally controlled sequence valve can serve as an unloading valve. In selection watch the port diameter / flow, pressure-adjustment range and pressure loss. For circuit design see g-01. (Note: hydraulic-system cleanliness is the key to life, target NAS 9 to 10 (general) / NAS 6 to 7 (servo). The relief valve at the pump outlet sets the maximum pressure; long relief flow causes heat, so prefer a variable pump or an unloading circuit. Pipe velocity reference: suction 0.5 to 1.5 m/s, pressure 3 to 6 m/s, return 1.5 to 3 m/s, to reduce loss and noise.)