How do you solve hydraulic-system creeping (low-speed juddering)?

Creeping is a jumping motion at low speed caused by abrupt friction-change. Causes: (1) the friction coefficient is non-linear with speed (large static-dynamic friction difference) — use low-friction seals (Glyd ring), plastic-coated guides, improved lubrication; (2) air in the system (cavitation) — bleed air, prevent cavitation, raise back pressure; (3) flow pulsation / pump wear — replace pump or add accumulator; (4) insufficient load stiffness, large guide clearance; (5) wrong oil viscosity (too low causes cavitation, too high causes stickiness). Countermeasures: raise system stiffness and back pressure, remove air, use servo / proportional valves for fine control, improve the friction pair. For seals see faq-26; for maintenance see g-01. (Note: the hydraulic-cylinder piston-rod diameter is set by speed ratio (blind/rod-end area ratio 1.3 to 2) and stability; slenderness over 10 needs Euler buckling verification. The accumulator charge pressure is 0.8 to 0.9 times the system minimum working pressure. On commissioning, bleed air by jogging first, then raise pressure step by step; oil temperature is best controlled at 40 to 60 C.)

Related references

tb-04 g-01

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL