Accumulator functions: (1) absorb pulsation and shock (pump pulsation, valve switching shock); (2) serve as emergency / auxiliary power source (hold pressure on power loss, compensate leakage); (3) recover energy. Types: bladder (fast response, common), piston (large capacity), spring (small low-pressure). Selection: calculate volume by function — small high-frequency capacity for pulsation absorption, volume by leakage rate and time for pressure holding, flow x time for emergency. Charge pressure is 0.8 to 0.9 times the system minimum working pressure (bladder), nitrogen charged. Note secure mounting, no welding, periodic gas-tight check. For design see g-01. (Note: hydraulic-system cleanliness is the key to life, target NAS 9 to 10 (general) / NAS 6 to 7 (servo). The relief valve at the pump outlet sets the maximum pressure; long relief flow causes heat, so prefer a variable pump or an unloading circuit. Pipe velocity reference: suction 0.5 to 1.5 m/s, pressure 3 to 6 m/s, return 1.5 to 3 m/s, to reduce loss and noise.)