For insufficient force, troubleshoot: (1) is the supply pressure up to standard (nameplate 0.4 to 0.6 MPa, actual line loss is large); (2) is the bore too small; theoretical force F = p x A then times efficiency 0.7 to 0.85; (3) is the load ratio too large (recommended 50% to 80% or below); (4) piston / seal wear causing internal leakage; (5) guide / load sticking raising friction. For slow action: (1) small pipe diameter, throttling at joints; (2) directional valve port too small, slow response; (3) poor exhaust (clogged silencer); (4) large load inertia. Countermeasures: add an air receiver for stable pressure, enlarge pipe diameter, use a quick-exhaust valve, choose a larger-port valve, check seals. For calculation see g-01. (Note: pneumatic air consumption is calculated from bore, stroke and actuation frequency, with a 20% to 30% margin for compressor selection. The triplet (filter / regulator / lubricator) should be near the point of use, with the correct inlet direction, and drain and replace the element periodically. The cylinder theoretical force must be multiplied by efficiency 0.7 to 0.85 and selected by a load ratio of 50% to 80% or below to prevent low-speed creeping.)