The triplet is standard in pneumatic systems: (1) filter (filter-regulator with water separator) — removes water and particles (5 micrometer common), manual drain at cup bottom, prevents component rust and sticking; (2) regulator — stabilizes working pressure and adjusts it, with a pressure gauge; (3) lubricator — atomizes lubricating oil into the air to lubricate cylinders / valves (can be omitted for oil-free systems). Maintenance: drain periodically, clean the element, add 32# turbine oil by the oil window; oil-free systems use self-lubricating seals. Layout: place as close as possible to the point of use, with the correct inlet direction. For design see g-01. (Note: insufficient air-source treatment is the main cause of pneumatic failure: water causes component rust and sticking, so automatic drains and dryers should be installed (dew point -20 C or below for precision). A clogged silencer blocks exhaust and slows action, so clean it periodically. The piping pressure-hold test leakage should be 0.1 MPa / 10 min or below; leakage often accounts for over 20% of air consumption. For oil-mist lubrication systems check the oil-level window and drip rate periodically (generally 1 to 2 drops per 1000 L of air); oil-free cylinders must use self-lubricating seals and avoid dry-start.)