Poor alignment is the main cause of early coupling and bearing damage. Requirements: (1) keep radial / angular deviation within the standard (rigid coupling 0.05 mm or below, elastic 0.1 to 0.3 mm / 0.5 degree or below); (2) use a dial indicator or laser alignment, not by feel; (3) leave expansion allowance for hot / cold alignment; (4) diaphragm / pin bolts must be tightened crosswise and symmetrically by torque (torque wrench), and nylon pins must not replace steel pins; (5) re-measure temperature rise and vibration after running. Wrong alignment raises the additional bending moment 2 to 5 times and halves bearing life. For alignment method see g-01; for bearings see faq-05. (Note: coupling selection flow: calculate the coupling torque Tc = K x T (K = 1.3 to 3.5 by shock) -> check the standard model so rated torque is not below Tc and rated speed is not below n -> verify the shaft hole and keyway (GB/T 3852) -> control installation alignment (rigid 0.05 mm or below, flexible 0.1 to 0.3 mm or below). Elastic parts age and need periodic replacement.)