① reduceunnecessaryoffinish-machined surface
② avoiddeep hole (length-to-diameter ratio>5)
③ avoidinternal cavity machining (fromexternal structure design)
④ reducenumber of tool changes (standardise chamfers/groove width)
⑤ avoidcurved surfaces (use flat surfaces instead of curves)
⑥ reducenumber of fixturings
⑦ avoidangled holes/angled planes
⑧ avoidthin-walled parts (distorts and is hard to machine)
⑨ standard drillprefer standard depth/diameter
⑩ Tighten up tolerance grades (cost rises sharply above IT8)
① Provide lead-in chamfers (≥ C1)
② symmetrical partsdesignpoka-yoke features
③ reducewire harness/routing of pipework
④ modular design (reducepart count)
⑤ use standard parts (reducecustom-made parts)
⑥ leave tool operating space
⑦ designmounting datum face
⑧ reduceadjustment work (locate by structure)
⑨ keep parts small and light (operable with one hand)
⑩ unify the connection method (such asuse hexagon sockets throughout)
① symmetrical weld design (weld both sides instead of one)
② pre-weld reverse deformation (preset deformation)
③ allow for shrinkage
④ step-back welding/skip welding
⑤ rigid fixturing (fixture)
⑥ reducebevel angleandweld volume
⑦ choose a sensiblewelding sequence
⑧ post-weld flame straightening
⑨ vibration ageingstress relief
⑩ post-weld heat treatment
Suction forceF=0.1×P×A×S/N
P—vacuum level (kPa)/A—suction cupeffective area (cm²)
S—safety factor (horizontal4/vertical8)
N—number of suction cups
Example: horizontal lifting of a 5kg workpiece, vacuum -60kPa, safety factor 4
A=F×N/(0.1×P×S)=5×9.8×4/(0.1×60×4)=8.2cm²
→ select φ32mm suction cups (8.04cm² effective area), 4 off
T=9550×P/n
T—torque (Nm)/P—power (kW)/n—speed (r/min)
Example1: 5.5kWelectric motor/1500r/min→T=9550×5.5/1500=35Nm
Example2: Outputtorque50Nm/speed200r/min→P=50×200/9550=1.05kW→select1.5kWelectric motor
Rule of thumb: the servo motor rated torque corresponds to about 70~80% of the maximum torque
T=F×Ph/(2π×η)×S
F—axial force (N)/Ph—lead (mm)
η—efficiency (ball0.9/trapezoidal0.4)/S—safety factor
Example: F=2000N/Ph=10mm/ball screwη=0.9
T=2000×10/(2×3.14×0.9)=3540Nmm≈3.5Nm
Select a motor with rated torque ≥ 4Nm (including a 1.2 safety factor)
Pump power P = p × Q / (60 × η)
P pump — motor power (kW) / p — working pressure (MPa)
Q—pump flow rate (L/min)/η—overall pump efficiency (0.7~0.85)
Example: p=10MPa/Q=40L/min/η=0.8
P=10×40/(60×0.8)=8.3kW→select11kWelectric motor
Related quick references: Data Quick ReferenceDataElectricalQuick Reference