Parallel-key selection in 5 steps: GB/T 1096 cross-section + strength check, a complete worked example

Summary

The parallel key is the most common form of shaft-hub connection; a wrong cross-section or key length leads to hub-bore crushing, a sheared key, or insufficient torque capacity. This article follows the flow of "select the cross-section by shaft diameter → set the key length by hub width → compute the bearing and shear stresses → compare with the allowable values", combined with the GB/T 1096 model range and the allowable-stress grading table, to give a complete worked example. After reading it you can complete the whole process from shaft diameter and torque to the key designation on your own.

Body

Application Scenario and Problem Background

A parallel key transmits torque through its sides while the top and bottom surfaces clear, and its dominant failure modes are crushing of the hub or shaft keyway (the weakest material, often the hub, fails first) and shear of the key itself. A common mistake is selecting the cross-section only from the shaft diameter without checking strength, so a brief overload shears the key; another is choosing the key length wrong: the ends of a round-ended Type A key do not bear, so the effective working length must be reduced by one key width, and substituting the nominal length skews the strength calculation.

A longer key is not necessarily better. Too long a key distributes the load unevenly along its length; with a limited hub width, take the key length as the hub width minus 5~10 mm, then round to the standard length series.

Selection Calculation

Core Formulas

Bearing strength: σp = 2 × T / (d × k × l)

Shear strength: τ = 2 × T / (d × b × l)

Effective length: Type A round-ended key l = L − b; Type B square-ended key l = L

Contact height: k ≈ h / 2

Parameter description

ParameterMeaningUnit
TTransmitted torqueN·mm
dShaft diametermm
bKey Widthmm
hKey heightmm
LKey nominal lengthmm
lEffective working lengthmm
kContact height between key and hub keywaymm

Recommended table 1: key cross-section selected by shaft diameter (common grades of GB/T 1095/1096)

Shaft diameter rangeRecommended key b×h
>17~22 mm6×6 mm
>22~30 mm8×7 mm
>30~38 mm10×8 mm
>38~44 mm12×8 mm
>44~50 mm14×9 mm
>50~58 mm16×10 mm
>58~65 mm18×11 mm
>65~75 mm20×12 mm

Recommended table 2: allowable stresses (key material 45 steel)

Service conditionAllowable bearing, steel hubAllowable bearing, cast-iron hubAllowable shear
Static load120~150 MPa70~80 MPa120 MPa
Light shock100~120 MPa50~60 MPa90 MPa
Impact60~90 MPa30~45 MPa60 MPa

Complete Worked Example

Given: shaft diameter d=50 mm, transmitted torque T=800 N·m (800000 N·mm), hub of 45 steel with a 100 mm width, steady static load.

Step 1: select the cross-section by shaft diameter.d=50 mm falls in the >44~50 grade, take b=14 mm, h=9 mm.

Step 2: set the key length.Hub width 100, take L=90 mm, round-ended Type A. Effective length l = L − b = 76 mm; contact height k = h/2 = 4.5 mm.

Step 3: check bearing.σp = 2 × 800000 / (50 × 4.5 × 76) = 93.6 MPa, less than the 120 MPa allowable for a steel hub under static load, acceptable.

Step 4: check shear.τ = 2 × 800000 / (50 × 14 × 76) = 30.1 MPa, far below the 120 MPa allowable shear; shear does not govern.

Conclusion:Select an ordinary Type A parallel key, designated Key 14×90 GB/T 1096 (45 steel); both strength checks pass.

Boundary comparison:When the torque rises to 1200 N·m, σp=140.4 MPa, above the lower allowable limit for a steel hub; switch to a 16×10 key or use a 180° double key (counted as 1.5 keys). A cast-iron hub allows only 70~80 MPa, so the 93.6 MPa of this case would crush it — replace the hub with steel or lengthen the key.

Result Verification and Pitfall Reminders

  1. The effective length of a Type A key must deduct the round ends.l=L−b; substituting L directly overestimates the strength by roughly the ratio b/L, about 20% when L=70 and b=14.
  2. The weak link in bearing is the hub.Take the allowable bearing by hub material; a cast-iron hub allows only about half that of a steel hub. With a steel shaft and steel hub the shaft keyway normally need not be checked separately — the hub keyway is the weakest.
  3. Woodruff keys and taper keys have limits on where they apply.A Woodruff key (GB/T 1099) suits small torques and tapered shaft ends; a taper key transmits torque by friction, centers poorly, and introduces eccentricity, so use it only for low-speed heavy loads where alignment is not critical — never in high-speed precision drives.

Suggested Illustrations

If you have no idea for the structure, browse the full-line 3D models (chip mounters, hot presses, etc., with parts lists) in the "MOULDL Model Library (mouldl Model Library)"; for data, check them again against the "BST Technical Handbook" to be safer.

This article was compiled by Baist Technology (BST) as a reference for mechanical selection.

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL