The parallel key is the most common form of shaft-hub connection; a wrong cross-section or key length leads to hub-bore crushing, a sheared key, or insufficient torque capacity. This article follows the flow of "select the cross-section by shaft diameter → set the key length by hub width → compute the bearing and shear stresses → compare with the allowable values", combined with the GB/T 1096 model range and the allowable-stress grading table, to give a complete worked example. After reading it you can complete the whole process from shaft diameter and torque to the key designation on your own.
A parallel key transmits torque through its sides while the top and bottom surfaces clear, and its dominant failure modes are crushing of the hub or shaft keyway (the weakest material, often the hub, fails first) and shear of the key itself. A common mistake is selecting the cross-section only from the shaft diameter without checking strength, so a brief overload shears the key; another is choosing the key length wrong: the ends of a round-ended Type A key do not bear, so the effective working length must be reduced by one key width, and substituting the nominal length skews the strength calculation.
A longer key is not necessarily better. Too long a key distributes the load unevenly along its length; with a limited hub width, take the key length as the hub width minus 5~10 mm, then round to the standard length series.
Core Formulas
Bearing strength: σp = 2 × T / (d × k × l)
Shear strength: τ = 2 × T / (d × b × l)
Effective length: Type A round-ended key l = L − b; Type B square-ended key l = L
Contact height: k ≈ h / 2
Parameter description
| Parameter | Meaning | Unit |
|---|---|---|
| T | Transmitted torque | N·mm |
| d | Shaft diameter | mm |
| b | Key Width | mm |
| h | Key height | mm |
| L | Key nominal length | mm |
| l | Effective working length | mm |
| k | Contact height between key and hub keyway | mm |
Recommended table 1: key cross-section selected by shaft diameter (common grades of GB/T 1095/1096)
| Shaft diameter range | Recommended key b×h |
|---|---|
| >17~22 mm | 6×6 mm |
| >22~30 mm | 8×7 mm |
| >30~38 mm | 10×8 mm |
| >38~44 mm | 12×8 mm |
| >44~50 mm | 14×9 mm |
| >50~58 mm | 16×10 mm |
| >58~65 mm | 18×11 mm |
| >65~75 mm | 20×12 mm |
Recommended table 2: allowable stresses (key material 45 steel)
| Service condition | Allowable bearing, steel hub | Allowable bearing, cast-iron hub | Allowable shear |
|---|---|---|---|
| Static load | 120~150 MPa | 70~80 MPa | 120 MPa |
| Light shock | 100~120 MPa | 50~60 MPa | 90 MPa |
| Impact | 60~90 MPa | 30~45 MPa | 60 MPa |
Complete Worked Example
Given: shaft diameter d=50 mm, transmitted torque T=800 N·m (800000 N·mm), hub of 45 steel with a 100 mm width, steady static load.
Step 1: select the cross-section by shaft diameter.d=50 mm falls in the >44~50 grade, take b=14 mm, h=9 mm.
Step 2: set the key length.Hub width 100, take L=90 mm, round-ended Type A. Effective length l = L − b = 76 mm; contact height k = h/2 = 4.5 mm.
Step 3: check bearing.σp = 2 × 800000 / (50 × 4.5 × 76) = 93.6 MPa, less than the 120 MPa allowable for a steel hub under static load, acceptable.
Step 4: check shear.τ = 2 × 800000 / (50 × 14 × 76) = 30.1 MPa, far below the 120 MPa allowable shear; shear does not govern.
Conclusion:Select an ordinary Type A parallel key, designated Key 14×90 GB/T 1096 (45 steel); both strength checks pass.
Boundary comparison:When the torque rises to 1200 N·m, σp=140.4 MPa, above the lower allowable limit for a steel hub; switch to a 16×10 key or use a 180° double key (counted as 1.5 keys). A cast-iron hub allows only 70~80 MPa, so the 93.6 MPa of this case would crush it — replace the hub with steel or lengthen the key.
If you have no idea for the structure, browse the full-line 3D models (chip mounters, hot presses, etc., with parts lists) in the "MOULDL Model Library (mouldl Model Library)"; for data, check them again against the "BST Technical Handbook" to be safer.