Knowledge Base › Injection Molding Machine › 2026-10-10_10_Injection Mold Cooling Channel Design Calculation_BST

Injection mold cooling channel design example: flow rate + Reynolds number + channel diameter right in one pass

Summary

For the cooling channel design of a 4-cavity PP mold, this article gives a complete self-consistent worked example in four steps: "heat to be removed per hour → cooling water flow rate (by allowable temperature rise) → channel diameter and flow velocity → Reynolds number check (turbulent ≥10000)". Readers can apply the formulas directly to select the channel diameter and water circuit layout and avoid uneven cooling and long cycles.

Body

Application Scenario and Problem Background

In injection molding the cooling time accounts for 60%~80% of the molding cycle, and whether the cooling channel design is sound directly determines the production cycle and the dimensional stability of the part. Two mistakes are common in engineering: first, drilling Ø6 or Ø8 channels from experience alone without checking the water flow rate and velocity, so the water flows laminarly in the channel and the heat transfer coefficient is only 1/3~1/5 that of turbulent flow, and the mold temperature will not come down; second, guessing the distance and spacing from the channel to the cavity wall, causing localized shrinkage marks and warping of the part.

The core of cooling channel design is that the water must be in turbulent flow inside the channel (Reynolds number Re≥4000~10000) for the heat transfer coefficient to be high enough, while keeping the inlet-outlet water temperature difference within 3~5 ℃ to avoid excessive temperature variation across the mold surface.

Selection Calculation

Core Formulas

Molds per hour:N = 3600 / T_cycle, where T_cycle is the molding cycle (s).

Heat to be removed per hour:Q = n_cav · m · N · c · (T_m - T_e), where n_cav is the number of cavities, m the part mass per cavity (kg), c the material specific heat (kJ/(kg·℃)), T_m the melt temperature, and T_e the ejection temperature.

Cooling water flow rate:m_w = Q / (c_w · ΔT_w), where c_w is the specific heat of water, 4.18 kJ/(kg·℃), and ΔT_w the allowable inlet-outlet temperature rise (℃). Volumetric flow Q_w = m_w / ρ_w, with ρ_w=1000 kg/m³.

Flow velocity in the channel:v = Q_w / A, where A = (π/4) · d² and d is the channel inner diameter.

Reynolds number:Re = v · d / ν, where ν is the kinematic viscosity of water, taken as 0.89×10⁻⁶ m²/s at 25 ℃. Turbulent flow requires Re≥10000.

Parameter description

ParameterMeaningUnit
T_cycleMolding cycles
n_cavNumber of cavitiescavities
mPart mass per cavitykg
cMaterial specific heatkJ/(kg·℃)
T_mMelt temperature℃
T_eEjection temperature℃
QHeat to be removed per hourkJ/h
ΔT_wAllowable cooling water temperature rise℃
Q_wCooling water volumetric flowm³/s
dChannel inner diameterm
vFlow velocity in the channelm/s
ReReynolds number—

Recommended Value Table

ItemRecommended valueNotes
PP specific heat c1.8~2.0 kJ/(kg·℃)Per the material grade data sheet
PP melt temperature T_m200~240 ℃Use the mid value for the calculation
Ejection temperature T_e60~90 ℃Take 80 ℃ for PP
Allowable cooling water temperature rise ΔT_w3~5 ℃Take 3 ℃ for precision parts
Channel inner diameter d6~12 mm8 mm is common for small and medium molds
Flow velocity in the channel v1.0~2.0 m/sBalancing heat transfer and pressure loss
Reynolds number Re≥10000Below 4000 is laminar flow with poor heat transfer
Distance from channel to cavity wall1.5~2.5 times the channel diameterToo close causes uneven cooling

Complete Worked Example

Given:PP material, the part being a mobile-phone battery housing, part mass per cavity m=80 g=0.08 kg, 4 cavities per mold, molding cycle T_cycle=25 s, melt temperature T_m=230 ℃, ejection temperature T_e=80 ℃, PP specific heat c=1.8 kJ/(kg·℃), cooling water inlet at 25 ℃, allowable temperature rise ΔT_w=5 ℃.

Step 1: molds per hour.

N = 3600 / 25 = 144 molds/h。

Step 2: heat to be removed per hour.

Total part mass per hour = 4 × 0.08 × 144 = 46.08 kg/h.

Q = 46.08 × 1.8 × (230 - 80) = 46.08 × 1.8 × 150 = 12441.6 kJ/h。

Equivalent power = 12441.6 / 3600 = 3.46 kW. Allowing for heat loss from the mold itself and heat carried in by the nozzle runner, multiply by a 1.2 safety factor; the design value is 4.15 kW.

Step 3: cooling water flow rate.

m_w = 12441.6 / (4.18 × 5) = 595.3 kg/h ≈ 9.9 L/min。

After multiplying by 1.2, about 11.9 L/min. The design water circuit is split into two parallel loops, each serving 2 cavities, with a flow per loop of about5 L/min。

Step 4: select the channel diameter and check the flow velocity.

Select a channel inner diameter d=8 mm, with a flow per loop of 5 L/min = 8.33×10⁻⁵ m³/s.

Channel cross-sectional area A = (π/4) × (0.008)² = 5.03×10⁻⁵ m².

Velocity v = 8.33×10⁻⁵ / 5.03×10⁻⁵ = 1.66 m/s, within the recommended range of 1.0~2.0 m/s.

Step 5: Reynolds number check.

Re = v · d / ν = 1.66 × 0.008 / (0.89×10⁻⁶) = 14900。

Re=14900 > 10000, in the fully turbulent region, with ample heat transfer coefficient.

Conclusion:Using Ø8 mm channels split into two parallel loops each serving 2 cavities, with 5 L/min per loop, a velocity of 1.66 m/s, and a Reynolds number of 14900, meets the cooling requirement of a 25 s molding cycle for 4-cavity PP parts.

Result Verification and Pitfall Reminders

  1. The channel must be neither too close to nor too far from the cavity wall.Take the distance as 1.5~2.5 times the channel diameter (12~20 mm for Ø8 channels). Too close leaves cooling marks on the cavity face; too far gives insufficient heat transfer. Take the circuit spacing as 3~5 times the channel diameter to ensure a uniform temperature field.
  2. Parallel loops must be flow-balanced.If two parallel loops have different resistance, the flow automatically favors the lower-resistance path and the other becomes "dead water". Add a throttle valve at each loop inlet, and during commissioning measure the outlet water temperature of each loop with an infrared thermometer, keeping the difference within 1 ℃.
  3. The setting on the water temperature controller is not the actual inlet water temperature.A 5 ℃ mold inlet-outlet water temperature difference is the design target, but in production the water temperature controller displays the inlet temperature; the outlet temperature must be measured at the loop outlet. If the measured difference exceeds 8 ℃, the flow is insufficient or a channel is partly scaled — clean it promptly.

Suggested Illustrations

If you are stuck on structure, browse the complete-line 3D models in the "MOULDL Model Library (mouldl model library)" (such as injection molding machines and palletizers, with parts lists); for the data, double-check with the "BST Technical Handbook" to be safer.

This article was compiled by Baist Technology (BST) as a reference for mechanical selection.

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »