Knowledge Base › Linear Motion › 2026-10-11_04_Trapezoidal Lead Screw Selection and Calculation_BST

Trapezoidal lead screw selection in 5 steps: get the torque and self-locking example right in one pass

Summary

Lifting, jacking, and fine-adjustment mechanisms commonly use trapezoidal lead screws, and poor selection often leads to slipping when stopped, motor stalling, and vibration or bending of long screws. This article follows five steps — lead selection, drive torque and self-locking, critical speed, column buckling, and thread bearing pressure — and gives a complete Tr30×6 example, so that after reading you can independently select a trapezoidal lead screw and judge whether it will self-lock.

Body

Application Scenario and Problem Background

Trapezoidal lead screws (Tr type) have a 30° thread angle and transmit motion by sliding of the thread pair; they are simple in structure and low in cost, and are self-locking with a single start and a small lead, so they are widely used in lift tables, cutter feeds, valve adjustment, and light-load positioning stages. Three mistakes are common: selecting the diameter from the load alone without calculating the drive torque, so an undersized motor stalls on startup; mistakenly choosing a multi-start, large-lead screw whose larger lead angle prevents self-locking, so a vertical lift slips when stopped; and failing to check critical speed and column buckling on a long-span screw, causing vibration at high speed or bending under compression.

Selection Calculation

Core Formulas

Parameter description

ParameterMeaningUnit
PhLead (equal to the pitch P for a single start)mm
d2Thread pitch diameter; for the Tr type take d2=d-0.5Pmm
λLead angle°
fFriction coefficient of the thread pair; for steel on bronze take 0.08~0.12—
ρFriction angle°
FAxial working loadN
TDrive torque (thread pair)N·m
drLead screw root diametermm
LSpan between supportsmm
CCritical-speed support coefficient: fixed-free 1.91; fixed-pinned 7.12; pinned-pinned 9.76; fixed-fixed 18.8—
λ1Column length coefficient: one end fixed and one end pinned 20.19; both ends pinned 9.87; both ends fixed 39.48; one end fixed and one end free 2.47—
EModulus of elasticity; for steel take 2.06×10^5MPaMPa
nWorking Speedr/min

Recommended Value Table

ItemRecommended valueNotes
Nominal diameter and lead seriesTr16×4、Tr20×4、Tr24×5、Tr30×6、Tr36×6、Tr40×7For light-load fine adjustment choose a small lead; for rapid travel choose a large lead
Friction coefficient fSteel on bronze nut 0.08~0.12With good lubrication take the lower limit, corresponding to a friction angle of 4.6°~6.8°
Self-locking criterionλ<ρ is the necessary condition; for lifting mechanisms λ≤3°~4° is saferWhen vibration or temperature rise lowers f, λ may approach ρ
Column safety factorStatic load 3~5; dynamic load 5~8A vertically lifting lead screw is under compression over its whole travel and must be checked
Critical-speed safety factorn≤ncr/3At high speed take n≤ncr/2
Number of engaged nut threadsSolid nut H≈5P, i.e. 5 threads; split nut H≈8P, i.e. 8 threadsWhen the bearing pressure is exceeded, lengthen the nut first
Permissible bearing pressure (steel-bronze)Horizontal drive 15~25MPa; vertical lift 8~12MPaWithout lubrication take the lower limit

Complete Worked Example

Given:Vertical lift table: axial load F=15000N (including the weight of the workpiece), lead screw support span L=2000mm (one end fixed, one end pinned), working speed n=80r/min, with self-locking required when stopped.

Step 1, preliminary selection of the size:A vertical lift requires self-locking, so choose a single-start thread; preliminarily select Tr30×6 (nominal diameter d=30mm, lead Ph=6mm), pitch diameter d2=d-0.5P=27mm, and root diameter dr=d-P=24mm.

Step 2, check self-locking:λ=arctan(6/(π×27))=arctan(0.0707)=4.05°; for steel on bronze take f=0.1, ρ=arctan(0.1)=5.71°; λ=4.05°<ρ=5.71°, so self-locking is satisfied and the table does not slip when stopped.

Step 3, calculate the drive torque:T=F·d2/2000·tan(λ+ρ)=15000×27/2000×tan(9.76°)=202.5×0.1720=34.8N·m; allowing for a thrust ball bearing friction coefficient of 1.15, T≈40N·m, and the drive motor and reducer are selected on this basis.

Step 4, check the critical speed:With one end fixed and one end pinned, take C=7.12: ncr=7.12×24/2000²×10^7=427r/min; the permissible [n]=ncr/3=142r/min>80r/min, so it passes.

Step 5, check column stability:I=π×24⁴/64=16286mm⁴, Fcr=20.19×π²×206000×16286/2000²=167kN; the safety factor n=167000/15000=11.1 is greater than the permissible 3~5, so it passes.

Step 6, check the thread bearing pressure:For a 30° thread form the working thread width is b=0.36P=2.16mm; with a solid nut H=5P=30mm and 5 threads, p=15000/(π×27×2.16×5)=16.4MPa, which exceeds the permissible 8~12MPa for vertical lift; switching to a split nut H=8P=48mm with 8 threads gives p=15000/(π×27×2.16×8)=10.2MPa, so it passes.

Conclusion:Select a Tr30×6 trapezoidal lead screw with a split bronze nut (H=48mm, 8 threads): drive torque about 40N·m, working speed 80r/min, and all four checks — self-locking, critical speed, column stability, and thread bearing pressure — pass.

Result Verification and Pitfall Reminders

  1. Self-locking is not an absolute safeguard: when vibration, shock, or rising temperature lowers the friction coefficient, λ approaches ρ, so a lifting mechanism must add an electromagnetic brake or a counterweight and cannot rely on thread self-locking alone.
  2. A multi-start, large-lead screw (Ph greater than 3P) has a large lead angle and high efficiency but does not self-lock; it is used only for rapid horizontal travel and is strictly forbidden in vertical applications.
  3. A lead screw in tension need not be checked for column buckling; only one in compression must be. A lifting lead screw is under compression over its whole travel, so above a span of 1500mm you must calculate Fcr and keep a safety factor of at least 3.
  4. Excessive bearing pressure is the main cause of early wear in trapezoidal lead screws: lengthen the nut to 8~10 threads first, and do not shorten the nut to reduce friction — halving the bearing pressure can multiply the service life several times over.

Suggested Illustrations

If you are stuck on structure, browse the full-line 3D models in the 'MOULDL model library (mouldl model library)' (such as hot presses and sorting machines, with parts lists); for data, double-check with the 'BST Technical Handbook' to be safer.

This article was compiled by Baist Technology (BST) as a reference for mechanical selection.

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL