E41-004 · Motor Selection · Vertical Lift Table Z-Axis · ★★
During braking on descent the inverter repeatedly reported overvoltage faults (OC/OV); the braking resistor surface temperature reached 200℃ and the resistor burned out after one month of service. The faster the descent speed and the heavier the load, the more frequent the fault.
The braking resistor was selected at only 200W/100Ω, but the actual braking power requirement calculates as follows: load mass m=500kg, descent speed v=0.5m/s, braking time t_brake=0.3s, so the regenerative energy is E=½mv²+mgh=½×500×0.25+500×9.8×0.15=62.5+735=797.5J and the braking power is P=E/t_brake=797.5/0.3≈2.66kW. The selected resistor rated power of 200W falls far short of the 2.66kW peak braking power requirement.
1) Calculate the regenerative energy in each braking cycle: E=½mv² (translational kinetic energy) + ½Jω² (rotational kinetic energy) + mgh (potential energy change)
2) Braking resistor power P=E×f×1.5 (f = braking frequency, 1.5 = safety factor)
3) Selection method: P_rated ≥ P_peak / braking duty cycle
4) This duty requires a braking resistor of ≥2kW (3kW/50Ω recommended)
5) Install a braking unit (built-in or external) together with a cooling fan
6) Set the overvoltage suppression parameters: extend the deceleration time and add a DC reactor
FT_12_Motor Selection Systematization, FT_13_Gearbox and Motor Matching Selection