E41-005 · Motor Selection · Five-Axis Machining Center Rotary Axis · ★★★★
After the rotary axis had run continuously for 10 revolutions the accumulated position error reached 0.2°, failing to meet the ±0.01° precision positioning requirement. The error returned to zero after homing, but accumulated gradually with continuous rotation, and the backlash also differed when the axis stopped in different directions.
An incremental encoder of 2500 lines/rev was selected, giving a resolution of 10000 pulses/rev = 0.036°/pulse after 4x multiplication by the drive. The position accuracy requirement of ±0.01° theoretically needs a resolution of at least 0.0036°/pulse, a gap of a factor of 10. In addition, an incremental encoder accumulates pulse-counting error during long operation and, without battery backup, has no multi-turn position memory, so homing is required after every power loss.
1) Accuracy calculation: ±0.01° required → encoder resolution must be ≤0.002° → at least 180000 pulses/rev needed
2) Select an absolute encoder of 17 bits or more (131072 pulses/rev = 0.0027°, basically sufficient)
3) A 22-bit multi-turn absolute encoder is recommended (4194304 pulses/rev, including 4096 turns of multi-turn data)
4) Fit a battery backup unit to retain the position memory during power loss
5) Optimise the mechanical drive train: eliminate worm gear backlash, pre-load the bearings and increase drive stiffness
FT_12_Motor Selection Systematization