Wrong Motor Protection Class Causes Water Ingress and Burnout (Food and Beverage Filling Machine Washing Station)

E41-006 · Motor Selection · Food and Beverage Filling Machine Washing Station · ★★

Problem Symptom

Three months after the motor started running its insulation resistance fell to zero and the stator winding burned out. On disassembly a large amount of water had collected inside the motor, the bearings had rusted and about 50ml of water had collected in the terminal box. All faults occurred after the daily high-pressure water gun cleaning process.

Root Cause

The motor was selected with an IP23 protection class (drip-proof, prevents solid foreign objects larger than 12mm), but the station is located in the filling and washing area of a food plant where a high-pressure water gun (5MPa) is used for a full wash-down every day; IP23 cannot prevent water jets from entering at all. The motor shaft extension had no water-slinging ring, and the cable entry of the terminal box was not waterproof-sealed, so water seeped in at two points: the shaft extension and the terminal box.

Correct Solution

1) Environmental assessment: where a high-pressure water gun is used for washing, a fully enclosed motor of IP65 or above must be selected (water-jet proof and dust proof)
2) Selection standard: motors in the food, beverage and pharmaceutical industries should use a stainless steel housing plus IP69K (able to withstand high-temperature, high-pressure steam wash-down)
3) Fit a water shield (a rain hood over the motor) and a water-slinging ring on the shaft extension
4) Use an IP68 waterproof aviation plug for the motor connection instead of a conventional terminal box
5) Drainage design: provide a drain hole at the lowest point of the motor and leave a drainage gap under the mounting base
6) Regularly inspect that the seals and drain holes remain clear