E41-007 · Motor Selection · Belt Conveyor Drive · ★★
The motor ran continuously at about 300rpm (10% of the rated 3000rpm), the temperature rise reached 90K (60K permitted) and the measured efficiency was only 40% (rated efficiency 85%) with the power factor down to 0.5. The motor's own cooling fan is almost ineffective at low speed, so heat accumulated.
The gearbox reduction ratio was chosen as 10:1, but the load only required an output speed of 30rpm (conveyor line speed 15m/min, roller diameter Φ160mm). The required ratio is n=motor speed/output speed=3000/30=100:1, but only 10:1 was selected, so the motor ran at an extremely low speed. At 300rpm the motor cooling fan delivers only 10% of its rated air volume and cooling is severely inadequate.
1) Calculate the load speed n_load=v/(π×D)=15/(3.14×0.16)=29.8≈30rpm
2) The optimal motor operating speed is 1500~3000rpm (the region of highest motor efficiency)
3) Reduction ratio i=n_motor_opt/n_load=2000/30≈66.7, select 60:1 or 70:1
4) Re-check: with i=70 the motor speed is 2100rpm (high-efficiency region) and the torque requirement drops by a factor of 7
5) Selection confirmation: three-motor scheme (4-pole motor at 1450rpm with a 48:1 ratio, or 6-pole motor at 960rpm with 32:1)
FT_13_Gearbox and Motor Matching Selection