E41-056 · Motor Selection · Plastic Extruder Drive · ★★★★
At low-speed start-up (50rpm) the extruder motor shook violently, current fluctuated by ±30%, and the low-speed range could not run stably. Above 500rpm normal operation was restored. Replacing both the inverter and the motor did not solve the problem.
An extruder is a typical constant-torque load and must deliver rated torque at low speed. However a standard three-phase induction motor (Class F insulation, S1 duty) was selected. In the 50rpm low-frequency state (5Hz) the inverter uses V/F control, and at low frequency the voltage compensation is insufficient, so the actual output torque is only 65% of rated value. At the same time the cooling fan on the standard motor delivers almost no air at 5Hz, and after 30 minutes of continuous low-speed running the winding temperature rise reached 85K. The load requires a constant 200Nm of torque while only 130Nm is actually available.
1) Constant-torque loads require a variable-speed dedicated motor (independent forced cooling fan plus 150% low-frequency torque capability)
2) An inverter motor can still deliver rated torque at 5Hz (a standard motor only 60~70%)
3) Selection: a YVP-180L-4 inverter motor, 22kW, constant torque from 5~100Hz
4) Use vector control in the inverter (V/F plus PG closed loop), where low-frequency torque reaches 200% of rated
5) If the motor cannot be replaced, add an independent cooling fan and derate the selection (use one frame size down)
6) Check the temperature rise for continuous low-speed running: forced cooling on an inverter motor keeps the temperature rise consistent at all speeds