E41-057 · Motor Selection · High-Speed Stamping Press Feed Servo · ★★★★

Problem Symptom

At a stamping frequency of 150 cycles per minute the servo motor started and stopped once every 0.4 seconds. After 2 hours of running the motor tripped on overtemperature and recovered after cooling down. On disassembly the rotor magnets were demagnetised and the rotor temperature had reached 150℃ (the magnets permit a maximum of 120℃).

Root Cause

In every cycle the servo motor accelerates from 0rpm to 3000rpm and decelerates back to 0rpm, with 0.1s for each of acceleration and deceleration, giving an angular acceleration of α=3141rad/s². The heat generated per start-stop cycle from copper loss, iron loss and mechanical loss is Q=∫I²Rdt≈180J; adding the heat residual after the regenerative braking energy is dissipated in the braking resistor (about 60J), the total heat per cycle is 240J. At 150 cycles per minute = 2.5Hz, heat generation is 600J/min=10W. Although the thermal power is not large, the rotor has poor heat dissipation conditions (a rotating part in an enclosed structure) and the 0.4-second cycle thermal time constant is far shorter than the motor's thermal time constant, so the heat cannot be transferred to the housing in time and accumulates inside the rotor.

Correct Solution

1) For high-frequency start-stop duty the motor's thermal capacity and thermal time constant must be checked
2) Reduce the acceleration/deceleration current peaks (extend the acceleration time to 0.15s to cut acceleration by 30%)
3) Use a low-inertia motor (rotor inertia reduced by 50%, heat generation reduced by 50%)
4) Add forced air cooling (an external cooling fan on an independent supply running continuously)
5) State the duty explicitly at selection: high-frequency start-stop applications require derating (rated torque ×0.7)
6) Braking energy recovery: use a common DC bus or a multi-axis energy sharing scheme to reduce braking heat