E41-058 · Motor Selection · Belt-Driven Fan · ★★★
Three months after the motor started running the front end bearing began to make abnormal noise and the vibration value rose from 2mm/s to 15mm/s. Overhaul showed the bearing cage broken and the balls worn. There were clear wear marks at the motor shaft extension.
The motor is 37kW at 1480rpm and uses a B-type V-belt drive (three V-belts). The belt tension calculated per standard is about 450N per belt; with a belt installation angle of 30° the resultant radial force is about F_radial=3×450×cos(30°)=1169N. The permitted maximum radial force on the motor front bearing (6312C3) is 800N (at 25mm from the shaft extension), so the actual 1169N exceeds the limit by 46%. The bearing carries an over-limit radial load, the contact stress between balls and raceways rises, the grease is squeezed out, and fatigue wear is accelerated.
1) Check the permitted radial force on the motor shaft extension in the catalogue data (the permitted value differs with the distance from the shaft extension)
2) The radial force of a belt drive is F=belt tension×cos(α)×number of belts
3) In this case F=1169N > permitted 800N, so the belt tension must be reduced or direct coupling adopted
4) Scheme A: change to direct coupling (zero radial force)
5) Scheme B: increase the pulley diameter to reduce the tension (from Φ200 to Φ300, tension reduced by 35%)
6) Scheme C: change to narrow V-belts (SPB type, three belts can be reduced to two, radial force down to 780N)
7) Scheme D: select the next larger motor frame (e.g. from the 37kW frame to the 45kW frame, where the bearing permits 1200N radial force)
FT_12_Motor Selection Systematization