E41-061 · Motor Selection · Large Induced Draft Fan · ★★★★
After the fan started, once the speed rose to 980rpm the whole machine vibrated violently with an amplitude of 12mm/s (7mm/s permitted), and the weld at the motor foot bolts cracked. Reducing the speed to 950rpm or raising it to 1010rpm reduced the vibration.
The motor weighs about 850kg and is mounted on a welded H-section steel base (No.20 channel, section 200×73×9mm). The base span is 2400mm and its natural frequency calculates as fn=1/(2π)×√(k/m)=1/(2π)×√(3EI/mL³)=1/6.28×√(3×206000×1780×10⁸/(850×2400³))≈16.5Hz. The motor rated speed 1480rpm×0.66=980rpm (running speed) corresponds to a rotational frequency of 16.3Hz, which matches the base natural frequency of 16.5Hz very closely (98.8% frequency coincidence), producing resonance. At resonance the amplitude magnification factor is Q≈1/(2ζ)=1/(2×0.02)=25, so the rotor unbalance exciting force is magnified 25 times.
1) The foundation natural frequency must avoid the working frequency by ±20%: fn≠(0.8~1.2)×f_work
2) With f_work=16.3Hz the foundation fn should be ≤13Hz or ≥19.6Hz
3) Lower the foundation natural frequency: reduce the section moment of inertia (change to No.14 channel) or increase the span
4) Raise the foundation stiffness: infill the base with epoxy resin concrete (increases mass and stiffness)
5) Install vibration isolators: rubber vibration pads (natural frequency 8~12Hz)
6) Rotor dynamic balancing: on-site dynamic balancing to reduce the unbalance exciting force (G2.5 grade)
7) Increase damping: weld damping ribs (T-type or L-type) to raise the structural damping ratio
FT_12_Motor Selection Systematization