E41-060 · Motor Selection · Spinning Machine Inverter Retrofit · ★★★
A standard motor (11kW, 4-pole) ran normally with a general-purpose inverter over the 5~50Hz range. But at 80Hz (4000rpm) the motor temperature reached 110℃, vibration increased noticeably and the current waveform was severely distorted.
A standard induction motor is designed for operation at the 50Hz mains frequency, and its bearings and rotor dynamic balance only satisfy speeds below 3000rpm. The inverter carrier frequency is 4kHz and the output contains many higher harmonics (5th, 7th, 11th and so on). Harmonic currents produce additional copper loss in the motor winding, and the harmonic field produces additional iron loss and high-frequency skin-effect loss in the rotor. At 80Hz (4000rpm) the total loss increases by 45% over the mains frequency, with harmonic losses accounting for 60% of the added loss. In addition, at 80Hz the motor speed exceeds the maximum design speed by 33%, rotor centrifugal force increases, and poor dynamic balance causes vibration.
1) The difference between an inverter motor and a standard motor: forced cooling fan, independent dielectric strength and special slot design
2) Motors fed by an inverter must be inverter-specific motors (e.g. the YVP series)
3) A standard motor on an inverter must be derated: derate by 1% per Hz above 50Hz
4) At 80Hz derate to 11×0.7=7.7kW (safety margin)
5) Install an output reactor (3% voltage drop) and a du/dt filter to suppress harmonics
6) Change to insulated bearings (to prevent shaft-current corrosion) or fit a grounding brush
7) The maximum speed must not exceed 1.2 times the motor rated speed (here 3000rpm → ≤3600rpm)
FT_12_Motor Selection Systematization