E41-116 · Motor Selection · Inverter-Fed Motor · ★★★
The motor ran normally when fed from the inverter but with obvious electromagnetic noise, and the vibration was three times that at mains frequency while the casing temperature was 15℃ higher than at mains frequency. The current waveform was severely distorted (THD≈12%).
The inverter carrier frequency is 2kHz and the output contains large amounts of 5th (250Hz) and 7th (350Hz) harmonics. The 5th harmonic produces a backward rotating field which interacts with the fundamental field to produce a 6th-order pulsating torque (300Hz), exciting the natural modes of the stator core and the casing and generating electromagnetic noise. Skin effect in the stator winding from harmonic currents increases copper loss by about 30%, and the harmonic field produces high-frequency iron loss in the rotor, giving a total loss increase of about 25%. In addition the motor bearings develop shaft current under harmonic current, accelerating bearing electrical erosion.
1) Install an output reactor (3% voltage drop) to filter out high-frequency harmonics
2) Raise the carrier frequency to above 4kHz (reducing harmonic content)
3) Select an inverter-specific motor (reinforced insulation plus independent cooling)
4) Install a dv/dt filter (to suppress voltage spikes and shaft current)
5) Change the motor bearings to insulated bearings (to prevent electrical erosion)
FT_12_Motor Selection Systematization