E41-080 · Motor Selection · Independent Cooling Fan for an Inverter Motor · ★★★
When the inverter motor ran at a low frequency of 25Hz its temperature quickly rose to 120℃. Inspection showed that all the plastic blades of the independent cooling fan had broken off and flown out, and the fan was spinning without delivering air.
The independent cooling fan was an axial fan with plastic blades rated at 2800rpm. However the actual duty of the inverter motor is long-term running at a low frequency of 25Hz (about 750rpm), while the independent fan, fed from its own supply, still ran at 2800rpm. The problem is that the fan blades were designed for 2800rpm, but with the motor running at low frequency the internal casing temperature can exceed 85℃, at which the tensile strength of the plastic blades (PA66+30%GF) falls by about 35%, and the material embrittles with long-term thermal ageing. Under the centrifugal force of high-speed rotation (centrifugal stress σ_c=ρ×ω²×r²/3≈12MPa), combined with the stress concentration at the blade root (Kt≈2.5), the equivalent stress reaches 30MPa, exceeding the PA66 fatigue limit of about 20MPa at 85℃, so fatigue cracks initiate at the blade root, propagate and the blades fracture.
1) Independent cooling fan selection: the blade material should withstand ≥120℃ (aluminium alloy or heat-resistant PPA recommended)
2) Match the fan speed: use a fan supplied from the same frequency as the motor (inverter auxiliary output)
3) Or use a temperature switch to raise the fan speed when the internal motor temperature exceeds 80℃
4) Periodic inspection: check the fan blades for cracks every month
5) Spare parts strategy: keep a spare fan (the plastic blade life is about 1 year)
FT_12_Motor Selection Systematization