E41-079 · Motor Selection · Gantry Planer Table Drive · ★★★
After six months of running the worktable reversal shock was large and the stopping position drifted. The no-load motor current fluctuated by ±8%, and teardown showed multiple broken rotor bars with a cracked end ring.
The motor reverses eight times per minute (once every 7.5 seconds), accumulating about 7680 reversals per day over 16 working hours per day, i.e. about 1.4 million reversals in six months. At each reversal the rotor current swings sharply from the positive rated value to the negative rated value, producing an extremely high di/dt, so the rotor bars are subjected to severe thermal stress and electromagnetic shock. The bars heat up and expand in the slot, then contract on cooling, and this cyclic stress combined with fretting wear against the core slot wall eventually causes fatigue fracture at the bar-to-end-ring joint. The fatigue life calculates as N_f=C/(Δσ)^m, where the stress amplitude Δσ=280MPa; from the S-N curve of 1050 aluminium bars N_f≈2×10⁵ cycles, corresponding to about 26 days in service, which broadly agrees with the six months to failure (allowing for the fact that the actual load was below rated).
1) Motors subject to frequent reversals should use copper-bar rotors (fatigue strength is 3 times that of aluminium bars)
2) Limit the reversal frequency: design a reversal interval of ≥5 seconds
3) Increase the rotor moment of inertia (add a flywheel) to reduce the reversal shock current
4) Change to a servo motor plus drive (programmable acceleration/deceleration curves, high current control accuracy)
5) Carry out periodic broken rotor bar detection (current spectrum analysis every 3 months)
FT_12_Motor Selection Systematization