E41-078 · Motor Selection · Vertical Water Pump Motor · ★★
Two hours after the new motor started running the bearing temperature reached 95℃, well above the permitted temperature rise. Turning the shaft extension by hand felt abnormally stiff. After draining the grease the temperature fell to a normal 55℃.
The motor bearings were overfilled with grease (filling 100% of the bearing housing space, against a standard of 33~50%). In a vertically installed motor the excess grease accumulates under gravity at the bottom bearing, and the rolling elements churning the grease generate large churning resistance. The churning power P_churn=0.5×ρ×ω³×R⁵×C_d (ρ = grease density, ω = angular speed, R = bearing outer diameter, C_d = drag coefficient) means the heat generated by churning excess grease is 5~8 times normal, directly overheating the bearing.
1) Grease filling standard: one third to one half of the internal bearing space (upper limit at low speed, lower limit at high speed)
2) For vertical motors reduce the fill to 30% of the bearing space (to prevent gravity-driven accumulation)
3) After greasing, turn the shaft by hand to confirm there is no stiff resistance
4) Provide a grease drain port so excess grease can be expelled
5) Use a metered grease gun (accuracy ±0.5ml) instead of estimating by eye
FT_12_Motor Selection Systematization