E41-077 · Motor Selection · Rolling Mill Main Drive Motor · ★★★★★
Under shock load the commutator surface developed severe ring fire (arcs spanning between positive and negative brushes), causing an instantaneous short circuit and tripping. On shutdown the commutator surface was badly burnt and the mica slots were carbonised.
The motor's rated current is 2000A and the shock peak current reaches 4500A (225% of rated), far beyond the commutation capability limit of a DC motor. The inter-segment voltage peak U_peak=K×B×v×L (K = commutation coefficient, B = air-gap flux density, v = peripheral speed, L = effective conductor length) rises sharply under shock current, with the inter-segment voltage jumping from the normal 15V to 42V (permitted limit ≤25V). Air breakdown between segments forms an arc, the high-temperature arc ionises the air and forms a conductive channel, arcing develops between adjacent commutator segments and grows into a ring fire.
1) Commutation capability check: inter-segment voltage peak ≤25V (≤18V without interpoles)
2) Improvement 1: add interpole windings (can reduce the shock inter-segment voltage by 40%)
3) Improvement 2: upgrade to a thyristor drive system and limit the current slew rate di/dt≤50A/ms
4) Improvement 3: install fast fuses plus overcurrent protection (response time ≤5ms)
5) Long-term solution: replace the DC drive with an AC inverter motor under vector control
6) Maintenance: polish the commutator every 500h and undercut the mica to a depth of 1~1.5mm