E41-076 · Motor Selection · Large Fan Drive · ★★★★
When the fan started the motor accelerated extremely slowly, taking 45 seconds from 0 to rated speed (normally 8~10 seconds), accompanied by a periodic buzzing sound. After shutdown, a no-load start was normal but the problem reappeared with load.
The motor is a 55kW cage induction motor whose cast-aluminium rotor bars developed thermal stress fatigue during long-term frequent starting, with three bars broken at the end ring. After the bars broke the equivalent rotor resistance increased, and the starting torque T_st∝(R_r/s)×U²/(R_r²+X²) calculated from 1.8 times the rated starting torque down to 1.1 times, while the fan load requires a starting torque of 1.3 times, so the start failed. The broken-bar fault also unbalances the rotor current, causing stator current fluctuation of about ±15%.
1) Broken rotor bar diagnosis: use current spectrum analysis to detect the (1±2s)f sidebands on either side of the supply frequency f
2) Once broken bars are confirmed the rotor must be replaced or recast with new bars
3) Design improvement: use a double-cage rotor (starting cage plus running cage) to raise the starting torque to 2.0 times
4) Limit the starting frequency: allow an interval of ≥30 minutes between starts, or use a soft starter
5) Variable-frequency start instead: YZR wound-rotor motor with a frequency-sensitive rheostat starter
FT_12_Motor Selection Systematization