E41-162 · Motor Selection · Cotton Mill Motor · ★★
After six months of running the cotton mill motor tripped on overheat, and the motor casing temperature reached as high as 110℃. Inspection showed the rear cooling fan cowl completely blocked with cotton lint, so no air could enter the fan.
The motor cooling fan draws cool air in at the rear through an axial fan and discharges it from the front after it has passed over the cooling fins. The air in a cotton mill contains large amounts of cotton lint fibre which is drawn into the fan cowl with the cooling air. The lint accumulates on the cowl filter mesh (5mm openings), blocking about 50% of the ventilation area after three months and completely blocking it after six months. After blockage the airflow falls from the design 500m³/h to about 50m³/h and the convective heat transfer coefficient drops from 30W/m²K to 5W/m²K. Cooling capability falls by about 90%, the motor can no longer dissipate heat effectively and the winding temperature quickly rises to 110℃ (Class B insulation permits 130℃, but long-term high temperature accelerates ageing).
1) Motors in cotton spinning and dusty environments should be fully enclosed self-ventilated (TEFC) type
2) Fit a removable filter (stainless steel mesh, 2mm openings, cleaned weekly)
3) Blow the fan cowl in reverse with compressed air every week
4) Monitor the motor temperature: PT100 with an alarm above 90℃
5) Or select a motor with a separate air duct (the cooling air does not pass through the motor interior)