E41-167 · Motor Selection · Inverter Motor Electromagnetic Noise · ★★★
When the inverter motor ran at 30~40Hz it emitted a sharp electromagnetic whine (about 8kHz), and the noise in a quiet workshop reached 85dB(A), exceeding the environmental requirement of ≤75dB(A).
The inverter carrier frequency was set to 2kHz, and the rising and falling edges of the PWM pulse produce an electromagnetic exciting force at integer multiples of the carrier frequency (2kHz, 4kHz, 6kHz, 8kHz...). The natural modes of the stator core laminations have a resonance peak near 8kHz, which is excited by the 8kHz electromagnetic force (4 times the carrier frequency), producing strong electromagnetic noise. The human ear is most sensitive at 8kHz, so the noise sounds particularly harsh. The relationship between noise magnitude and carrier frequency is: the lower f_carrier, the greater the current harmonic content and the stronger the electromagnetic noise; the higher f_carrier (≥4kHz), the lower the noise but the greater the switching loss.
1) Raise the carrier frequency: 2kHz→8kHz (electromagnetic noise reduced by about 10dB)
2) Select a low-noise inverter motor (skewed stator slot design to reduce the electromagnetic exciting force)
3) Fit an acoustic enclosure on the motor (multi-layer composite structure, sound reduction ≥15dB)
4) Install a sine-wave filter on the output (completely removes the PWM harmonics)
5) Use random PWM modulation in the inverter (spreads the harmonic energy and lowers the peak)
FT_12_Motor Selection Systematization