E41-174 · Motor Selection · Motor Used in a High-Altitude Region · ★★★
A 37kW rated motor used at an altitude of 3000m with an actual load of 35kW burned out its winding after one year of operation. The user had selected the power for plain-level conditions without applying the high-altitude derating factor.
The thin air at high altitude reduces the cooling capability. At 3000m the air density is ρ_h=ρ_0×(1-0.0226×H)^4.256=1.2×(1-0.0226×3)^4.256≈0.73kg/m³ (about 61% of the plain-level value). The cooling capability of the motor's self-ventilating fan is proportional to the air density, so the derating factor K_altitude≈(ρ_h/ρ_0)^0.5=0.78. The usable power of the 37kW motor at 3000m is P_available=37×0.78≈28.9kW. The actual load of 35kW is greater than 28.9kW, so the motor runs about 21% overloaded continuously. The winding temperature is θ=θ_ambient+(P_load/P_rated)^(1.6)×θ_rise=30+(35/28.9)^1.6×80≈30+1.22×80=127.6℃. The Class B insulation limit is 130℃, and at 127.6℃ the life is only about 20,000 hours (about 2.3 years); the actual failure after one year is due to higher peak values with the fluctuating load.
1) Motors at high altitude must be corrected for altitude: P_h=P_0×K_h
2) Derating factors: 1000m/0.98, 2000m/0.95, 3000m/0.88, 4000m/0.82
3) In this case 37kW→37×0.88=32.6kW (an actual load of 35kW → a 45kW motor is needed)
4) Or select a high-altitude special motor (reinforced insulation plus a larger fan)
5) Combined ambient temperature and altitude correction: P_corrected=P_rated×K_temp×K_alt
FT_12_Motor Selection Systematization