E41-320 · Motor Selection · Enclosed Motor Cooling · ★★★
When the enclosed motor (TEFC, 75kW) ran at rated load the casing temperature was unevenly distributed, with 95℃ at the drive end and 70℃ at the non-drive end. The winding insulation in the hotter region aged prematurely.
In the internal cooling duct design the cooling air is drawn in by the fan at the non-drive end, flows over the cooling fins on the outside of the stator core and is discharged at the drive end. However the drive end is usually installed close to the driven equipment (such as a fan or pump) and sits in the equipment's thermal radiation zone (for example a pump body at about 80℃). Although the external airflow at the drive end is good, it is heated by radiation from the driven equipment and the cooling efficiency falls. At the same time the drive-end bearing generates more heat (about 30W) than the non-drive end (about 15W). The uneven internal temperature distribution makes the drive-end winding temperature rise 25K higher than the non-drive end, so the insulation life L=L_rated×2^((θ_rated-θ_actual)/10)=2^(80-105)/10≈2^(-2.5)=0.177, meaning the drive-end winding life is only 17.7% of the rated life.
1) When installing the motor, fit a heat shield between the drive end and the driven equipment (ceramic fibre plus a stainless steel reflector plate)
2) Fit an independent auxiliary fan at the drive end of the motor (forced cooling of the drive-end casing)
3) Select a motor with a ribbed casing (cooling area increased by 30%)
4) Ensure ventilation all around the motor installation position (≥200mm from walls)
5) Fit a PT100 temperature sensor at the drive-end winding inside the motor (alarm above 90℃)
FT_12_Motor Selection Systematization