E41-319 · Motor Selection · Motor Repair Shaft Extension Keyway · ★★
After replacing the motor during repair the coupling could not be fitted, and measurement showed the keyway width on the new motor shaft extension deviated by 0.05mm (the tolerance should be +0.018/-0, but the actual was -0.032mm).
The new motor shaft extension was machined to the standard: Φ42k6 (+0.018/+0.002mm), keyway width 12P9 (-0.018/-0.061mm). The measured shaft extension Φ42.002mm was acceptable, but the keyway width was 11.968mm (-0.032mm, which exceeds the P9 lower limit of -0.061 and is in fact too wide). The coupling bore keyway width is 12N9 (-0.018/-0.061mm), measured 12.005mm. The total clearance is shaft keyway width 11.968mm + key width 11.990mm + coupling keyway width 12.005mm = 0.027mm, but because the keyway is too wide the key tilts in the slot (by about 0.05mm), so line contact replaces face contact on the key flanks and local bearing stress is concentrated. The coupling cannot be pushed fully home during installation because the key is skewed.
1) Machine the motor shaft extension keyway to the standard tolerances (GB/T 1095-2003)
2) Measure the shaft extension dimensions and keyway width before installation (outside micrometer plus keyway plug gauge)
3) Key fit standard: key width tolerance h8, keyway width tolerance P9/N9/Js9
4) The contact area between the key flanks and the keyway must be ≥70% (checked by the blueing method)
5) A non-conforming keyway can be repaired: keyway too wide → fit a larger key; keyway skewed → re-broach
FT_12_Motor Selection Systematization