E41-318 · Motor Selection · Vibrating Screen Drive Motor · ★★★★
The 30kW vibrating screen drive motor tripped on an earth fault after one year of running, and teardown showed the stator winding end banding cords broken, with the end windings rubbing against each other under vibration until the insulation was worn through and a turn-to-turn short circuit occurred.
The vibrating screen drive motor operates in a severe vibration environment (acceleration a=8g, frequency 16Hz). The stator winding end is subjected to an inertia force F=m×a=0.5×8×9.8≈39N in vibration (the mass of a single coil end is about 0.5kg). The end banding cord (impregnated glass tape) wears and breaks under sustained vibration, so the coil ends lose their constraint and rub against each other. The inter-coil insulation (polyester film plus the enamelled wire lacquer film) is worn through by the rubbing, bare copper touches bare copper → turn-to-turn short circuit → the short-circuit current produces sparks that ignite the insulation → phase-to-phase short circuit and tripping. In manufacture only two bands were applied (four are required at critical locations) and the banding tension was uneven (tight areas carried more load and wore out faster).
1) For vibration duty the stator end winding must be more heavily banded (four bands of impregnated glass tape plus varnish curing)
2) Fit insulating spacer blocks between the end windings (epoxy resin board, to prevent mutual rubbing)
3) Select a reinforced motor (specially designed for vibration duty, with the end winding encapsulated)
4) Isolate the vibration source: fit a vibration-damping base to the motor (rubber vibration pads, isolation efficiency ≥90%)
5) Periodically test the motor insulation resistance (once per quarter)
FT_12_Motor Selection Systematization