Insufficient Cooling at Low Speed When Running on an Inverter Causes Overheating (Constant-Torque Load)

E41-331 · Motor Selection · Inverter Motor Low-Speed Cooling · ★★★★

Problem Symptom

When the inverter motor ran at a low speed of 10Hz (constant-torque load, output power 15% of rated) the casing temperature reached 95℃ (only 60℃ at rated speed). The motor's self-ventilating fan does not deliver enough air at low speed.

Root Cause

At 10Hz (300rpm) the inverter motor speed is 20% of rated (1480rpm), and the self-ventilating fan airflow Q∝n³, so at 10Hz the airflow is only 0.2³=0.008 (0.8%) of the rated speed value. The cooling capability is severely inadequate. With a constant-torque load the torque output at low speed approaches rated, the current is about 80% of rated and the copper loss I²R is about 64% of rated. The heat generated is about 64% of rated, but the cooling capability is only 0.8% of rated, and at the thermal equilibrium point the temperature is T=T_ambient+P_loss/R_th, where the thermal resistance R_th is inversely proportional to the airflow, giving R_th_10Hz=R_th_rated×(Q_rated/Q_10Hz)=0.1×(1/0.008)=12.5K/W. Then T=30+0.64×P_loss_rated×12.5=30+0.64×5000×12.5×10⁻³=30+40=70℃ (P_loss_rated≈5kW, 0.1K/W per watt gives 50K, 0.64×50=32K, so 30+32=62℃). The actual 95℃ shows that besides copper loss there is also iron loss (frequency dependent) at low speed, and that the cooling conditions are worse than theory predicts.

Correct Solution

1) An inverter motor running at constant torque at low speed (<20% of rated speed) must have an independent cooling fan fitted
2) The independent fan is fed from its own supply (constant speed, unaffected by the motor inverter)
3) Select an inverter-specific motor (with an independent cooling fan built in)
4) Derate the motor: at 10Hz the permissible output torque falls to 60% of rated torque
5) Or change to a low-speed high-torque direct drive motor (no gearbox needed, high efficiency at low speed)

Checklist

References

FT_12_Motor Selection Systematization