E41-332 · Motor Selection · Motor Earthing Protection · ★★★★★
A portable electric tool (hand-held grinder, 1.5kW) used in a humid environment had a live casing (110V to earth), and the operator was injured by electric shock.
The earth wire of the electric tool (yellow and green dual-colour) was disconnected at the plug (the earth screw inside the plug was loose), so the tool casing was not effectively earthed. The insulation resistance of the motor winding inside the tool fell from 500MΩ to about 0.5MΩ when damp (humidity 90%), with a leakage current of about 0.5mA, which is insufficient to trip a 30mA residual current device. However, when the tool was used in a humid environment the operator's hand (a wet hand with a contact resistance of about 1kΩ) touched the casing while the other foot stood on damp ground (earth resistance about 500Ω), forming a current path: winding leakage → casing → hand → body → foot → earth. The leakage current I=U/(R_human+R_ground)=110/(1000+500)=73mA, far above the safe current of 30mA, causing the electric shock injury.
1) The motor casing must be reliably earthed (earth resistance ≤4Ω)
2) Check the integrity of the earth wire before using a portable electric tool
3) Fit a residual current device (operating current ≤30mA, operating time ≤0.1s)
4) Use an isolation transformer in humid environments (safety voltage, so no shock even with leakage)
5) Periodically test the insulation resistance of the electric tool (every quarter, ≥1MΩ)
FT_12_Motor Selection Systematization