Coupling Elastomer Does Not Match the Motor Shaft Extension Size (Repair Replacement)

E41-333 · Motor Selection · Motor Repair Coupling Matching · ★★★

Problem Symptom

After replacing the motor during repair the coupling could not be installed: the new motor shaft extension was Φ48mm while the original coupling bore was Φ42mm. The motor model was unchanged but a change of manufacturer gave a different shaft extension size.

Root Cause

The same motor model (Y2-200L-4, 30kW) from different manufacturers (factory A to factory B) differs in shaft extension size. Factory A follows GB/T 756 (shaft extension Φ48k6) and factory B follows JB/T 10391 (shaft extension Φ48k6), so in theory they should agree. But measurement showed the factory A shaft extension at Φ48.015mm (the k6 upper limit) and the factory B shaft extension at Φ48.030mm (0.015mm out of tolerance). The coupling bore is Φ48H7 (+0.025/0), so with factory A the fit is a clearance of 0.010mm (an interference of about 0.005mm), while with factory B it is an interference of 0.030mm, which exceeds the coupling's standard fit requirement. The repair staff forced the coupling on with a sledgehammer, damaging the motor bearing. Neither the shaft extension dimensions nor the coupling bore were measured before the replacement.

Correct Solution

1) The shaft extension dimensions must be measured before replacing the motor (diameter plus keyway width plus coaxiality)
2) Coupling bore to motor shaft extension fit: H7/k6 recommended (interference 0.002~0.025mm)
3) If the shaft extension is oversize, ream the coupling bore to suit the measured shaft extension
4) If the shaft extension is undersize, apply bearing retaining compound (Loctite 638, filling gaps up to 0.15mm)
5) Forcing a coupling on with a sledgehammer is strictly prohibited (bearing damage plus core loosening)

Checklist

References

FT_12_Motor Selection Systematization

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL