Resonance of the Motor Foundation Causes Fatigue Fracture of the Foundation Bolts (Centrifugal Compressor)

E41-334 · Motor Selection · Centrifugal Compressor Motor Foundation · ★★★★

Problem Symptom

After two years of running the foundation bolts (M30) of the centrifugal compressor motor fractured at the thread root and the compressor vibrated violently and shut down. The fracture surface showed the typical fatigue beach marks.

Root Cause

The critical speed analysis of the motor-compressor system was incomplete, and the working speed (1480rpm, 24.7Hz) was close to the natural frequency of the motor foundation (steel structure, about 24Hz), a difference of only 0.7Hz (about 2.8%), producing resonance. The resonant magnification factor is Q≈1/(2ζ)=1/0.04=25 (ζ=0.02, the damping ratio of the steel structure). The normal unbalance force F=0.01×m×r×ω²≈500N is amplified at resonance to 500×25=12500N. The M30 (grade 8.8) foundation bolts have a preload F_pre=0.7×σ_s×A_s=0.7×660×561≈259kN and an effective friction force F_fric=F_pre×μ=259×0.15≈38.9kN. Since 12500N is less than 38900N the bolts do not loosen. However in resonance the bolts carry an alternating tensile force (about 12.5kN), giving a stress amplitude Δσ=ΔF/A_s=12500/561≈22.3MPa against a bolt fatigue limit σ_a≈50MPa (10⁷ cycles, grade 8.8). At 22.3MPa against 50MPa there should in theory be no fatigue fracture. But machining defects exist at the thread root (turning marks, stress concentration factor Kt≈3.5), so the actual peak stress amplitude is σ_a_peak=Kt×Δσ=3.5×22.3=78MPa > 50MPa, giving fatigue fracture after about 5×10⁶ cycles (two years).

Correct Solution

1) The natural frequency of the motor foundation must avoid the working frequency by ±20%
2) Reinforce the foundation: add gusset plates or increase the structural stiffness to raise the natural frequency above 35Hz
3) Or install vibration isolators (rubber or spring, so that the working frequency / natural frequency ≥3)
4) Roll the bolt thread roots to introduce residual compressive stress (fatigue strength up by 50%)
5) Inspect the bolts regularly (once a year, magnetic particle testing for thread root cracks)