E41-335 · Motor Selection · Motor Fan Rubbing After Maintenance · ★★
After reassembly following motor maintenance the motor emitted a harsh rubbing noise during running and tripped on overheat after about 30 minutes. Inspection showed the fan blades rubbing against the cowl with about 5mm of blade wear.
During maintenance the fan cowl was removed, and on refitting it was not aligned, so the gap between the cowl and the fan changed from the normal 5mm to 0mm (the deformed cowl squeezed the fan). The fan (nylon 66+30%GF, outer diameter Φ280mm) rubs against the cowl at high rotational speed (1480rpm, peripheral speed 21.7m/s), and the frictional heating locally melts the nylon blades, wearing about 5mm off the tips. After the wear the fan diameter falls to Φ270mm (3.6% smaller), so the airflow Q∝D³≈0.964³=0.896, a reduction of about 10%. At the same time the drag from the friction increases the motor load and the current rises from the rated 110A to 120A (9% over), overheating the motor. The maintenance staff did not turn the shaft by hand after installation to check the fan-to-cowl clearance (there should be no rubbing noise when barring the motor).
1) After fitting the fan cowl the motor shaft must be turned by hand (confirm there is no rubbing noise)
2) The clearance standard between fan and cowl: radial ≥5mm, axial ≥10mm
3) A worn nylon fan must be replaced (it cannot be repaired)
4) Tighten the fan cowl bolts diagonally (to prevent skew)
5) After maintenance run the motor unloaded for 30min first (check vibration, noise and current)