Heavy Dust Accumulation on Motor Cooling Fins Reduces Cooling Efficiency (Foundry Shop)

E41-479 · Motor Selection · Foundry Shop Motor Cooling · ★★★

Problem Symptom

Three months after the foundry motor (110kW) started running the winding temperature rose from 70℃ to 95℃, and inspection showed the spaces between the motor casing cooling fins packed with a mixture of foundry dust and oil sludge.

Root Cause

The air in the foundry contains large amounts of foundry dust (silica sand plus resin combustion products, particle size 1~50μm) and oil mist (release agent). The motor cooling fan draws in this dusty air and the dust settles between the casing cooling fins. After three months the 5mm gaps between the 30mm high fins are completely filled with the dust and oil sludge. Once filled the cooling area falls from the original A=π×D×H×N=3.14×0.4×0.3×40≈15m² to about 3m² (the dust has a thermal conductivity of about 0.2W/mK, so the fin pack is equivalent to a 2mm thick dust layer). The convective heat transfer coefficient falls from 30W/m²K to about 15W/m²K (the duct is blocked and the airflow drops by about 50%). The cooling power becomes P_cool=h×A×ΔT=15×3×50=2250W, only 10% of the design value (30×15×50=22500W). With cooling inadequate the winding temperature rises from 70℃ to 95℃, a temperature rise of 125% (up 25K), and the insulation life L=L_rated×2^(-Δθ/10)=2^(-2.5)=0.177, so the life falls to 17.7% of the rated value.

Correct Solution

1) Motors in dusty environments should be TEFC fully enclosed type (the fins are inside and not exposed to dust)
2) Blow the cooling fins down with compressed air once per shift (reverse blowing, from the inside out)
3) Fit a filter on the motor cooling duct (stainless steel mesh, 10 mesh, washed weekly)
4) Select a motor with an independent cooling tube (the cooling tube circulates in a closed loop, unaffected by dust)
5) Monitor the motor temperature online (PT100 winding temperature alarm above 90℃)

Checklist

References

FT_12_Motor Selection Systematization