Grease Migration in a Vertical Motor Blocks the Grease Drain (Condensation Backflow)

E41-478 · Motor Selection · Vertical Motor Bearing Grease Blockage · ★★★

Problem Symptom

One year after the vertical water pump motor (90kW) started running the bearing temperature rose and grease squeezed out of the drain as a thin oil. The drain hole was blocked by solidified grease.

Root Cause

The vertical motor's bearings are at the top of the motor and the grease slowly flows downward under gravity (the flow rate of lithium complex grease at 60℃ is about 20mm/month). After one year about 30% of the grease in the upper bearing housing has flowed down to the lower drain hole. The drain hole (Φ6mm) is blocked at low temperature (after shutdown with an ambient temperature of 0℃) by solidified grease (NLGI#2 lithium complex grease approaches a solid at 0℃). On the next start the blocked drain prevents the excess grease from escaping, so it accumulates at the bottom of the bearing housing. The accumulated grease generates extra heat as it is churned (about 15W of churning power), raising the bearing temperature by 10℃. At the same time the blocked drain makes it impossible to judge whether the greasing is sufficient by observing the discharge, so the operator wrongly concludes that grease is short and over-greases, worsening the problem.

Correct Solution

1) Inspect the vertical motor drain hole regularly (once a month, clearing it with a thin wire)
2) Select a grease that does not readily flow, NLGI#3 lithium complex (higher consistency)
3) Orient the drain opening downwards (gravity discharge, less clogging)
4) After greasing, run at low speed for 30min and confirm that old grease leaves the drain
5) Or fit a grease recovery cup (a transparent cup at the drain outlet so the discharge can be observed)

Checklist

References

FT_12_Motor Selection Systematization

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »