Knowledge Base › Selection Error Cases › Coupling installation difficulty due to excessive radial runout at motor shaft extension (shaft-extension machining quality)

Coupling installation difficulty due to excessive radial runout at motor shaft extension (shaft-extension machining quality)

E41-492 · Motor Selection · Excessive Shaft-Extension Runout · ★★★

Problem Description

A new motor's shaft-extension radial runout was 0.06 mm (standard ≤0.03 mm); after coupling installation alignment was difficult and the elastomer wore faster.

Root Cause

Radial runout tolerance of the motor shaft extension: per GB/T 756, runout ≤0.03 mm when the extension length is 100 mm. The new motor's factory test report showed 0.06 mm runout (double the limit), but the user installed it without incoming inspection. The 0.06 mm runout causes a radial deviation after coupling installation (deviation equals half the runout, about 0.03 mm). Running the coupling at 0.03 mm radial deviation, the elastomer undergoes alternating squeezing. Meanwhile the runout makes the coupling rotation center not coincide with the motor axis, producing an extra radial force F = K × δ = 800 × 0.03 = 24 N (K is the coupling radial stiffness ~800 N/mm), adding load to the motor bearing. The motor bearing (6308) allows a radial force of about 800 N, so 24 N is negligible. But the coupling elastomer, at 0.03 mm deviation, wears unevenly and its life drops about 30%.

Corrective Solution

① Incoming inspection of new motor: check shaft-extension radial runout (dial indicator, standard ≤0.03 mm)\n② If runout exceeds limit, return the motor or rework it (grind extension until runout meets spec)\n③ Use a dial indicator to check alignment deviation when installing the coupling\n④ Choose a coupling that allows larger deviation (e.g., jaw type allows radial deviation ≤0.1 mm)\n⑤ Tight quality control of the motor supplier (require factory runout ≤0.02 mm)

Checklist

Reference

FT_12 Systematic Motor Selection

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL