E41-491 · Motor Selection · Motor Fan-Blade Imbalance · ★★★
A motor (160 kW) saw vibration rise from 3 mm/s to 9 mm/s after fan repair; spectrum analysis showed the 1× frequency (24.7 Hz) with the largest amplitude. The balance weight on the fan blade had fallen off.
The motor fan is dynamically balanced at manufacture (grade G6.3, allowable unbalance about 5 g·mm). During repair the fan was removed and refitted; the balance weight on the blade (a steel piece welded to the blade back, about 3 g) fell off during handling (weld cracked). Once unbalanced, at 1480 rpm it produces an unbalanced centrifugal force F_unbalance = m × r × ω² = 0.003 × 0.1 × 155² ≈ 7.2 N. This 7.2 N unbalance force produces about 9 mm/s vibration at the motor front bearing housing (considering bearing-housing stiffness ~1 × 10⁷ N/m, displacement δ = F/K = 7.2/1 × 10⁷ = 7.2 × 10⁻⁷ m ≈ 0.72 μm, converted to vibration velocity about 2 mm/s; the gap from the measured 9 mm/s indicates a resonance amplification factor as well). The 1× frequency vibration is prominent with stable phase.
① After fan removal/refit, re-balance dynamically (on a dedicated balancing machine)\n② Weld the fan balance weight securely (weld length ≥10 mm, inspect after welding)\n③ Measure vibration after fan installation (1× frequency vibration ≤1.8 mm/s passes)\n④ Or use a self-balancing fan (blades bolted, balance adjustable/replaceable)\n⑤ Note in the repair record whether the fan was re-balanced
FT_12 Systematic Motor Selection