E41-494 · Motor Selection · Single-Phase Motor Start-Capacitor Failure · ★★★
A single-phase motor (2.2 kW, capacitor-start/capacitor-run) hummed but would not turn over at start, only starting after the shaft was turned by hand. Inspection found the start capacitor had dropped from 200 μF to 80 μF.
The start capacitor of a single-phase motor (type CBB60, 200 μF, 450 VAC) gradually loses capacitance during long-term use (3 years). The dielectric (polypropylene film) ages under prolonged electric field and temperature (about 60℃), its permittivity ε drops, and the effective capacitance falls from 200 μF to about 80 μF (a 60% drop). The start-capacitor value sets the starting torque T_st ∝ C × U²; after a 60% loss the starting torque drops to 0.4× the rated starting torque. When the load (belt-driven fan) static friction torque exceeds 40% of rated torque, the motor cannot start. After the shaft is turned by hand, the motor keeps running under the run capacitor (25 μF, whose value is normal — the run capacitor mainly provides phase shift, is small but runs continuously).
① Replace single-phase motor start capacitors periodically (every 3 years)\n② Check capacitance with a multimeter capacitance range (≥80% of nominal is acceptable)\n③ Use long-life start capacitors (type CBB65, metallized polypropylene film, 10000 h life)\n④ When the motor has starting difficulty, check the start capacitor first\n⑤ Or use an electronic start module (no capacitor, solid-state switch, longer life)
FT_12 Systematic Motor Selection