E41-008 · Ballscrew Selection · Heavy Gantry Mill Z-Axis · ★★★★
During machining the ballscrew emitted a sharp abnormal noise, then fractured by bending almost instantly; the workpiece surface showed obvious chatter marks and the tool tip chipped. Fracture occurred in the upper-middle of the screw, with a typical bending-fatigue fracture appearance.
Ballscrew diameter d = 32 mm, support span L = 1440 mm, slenderness ratio L/d = 45 far exceeds the safe value (recommended ≤30). Axial load F = 12 kN, with no column-stability check. Euler critical load Pcr = π²EI/(μL)²; for both ends fixed μ = 0.5, I = πd⁴/64 = 51472 mm⁴, E = 206 GPa, Pcr = π² × 206000 × 51472 / (0.5 × 1440)² ≈ 10 kN. The actual load 12 kN exceeds the critical load by 20%, so the column buckled and fractured.
① Check critical load with Euler's formula: Pcr = π²EI/(μL)², safety factor ≥3
② Increase ballscrew diameter to d = 50 mm (I = 306796 mm⁴, Pcr increases 6×)
③ Shorten the support span: add an intermediate support bearing block at the middle of the screw
④ Change the support to both-ends-fixed (μ = 0.5) to improve anti-buckling capability
⑤ Check formula: d ≥ ∛(64 × P × s × L² × μ²)/(π³ × E), where s is the safety factor
⑥ Selection confirmed: d = 50 mm, p = 10 mm, both-ends-fixed support
FT_11 Ball Screw Selection