E41-012 · Ballscrew Selection · Manual Lift Table · ★★
Operators reported the handwheel for adjusting the lift table was very heavy, causing forearm soreness after a day's work. Measured handwheel force reached 120 N (ergonomic recommendation ≤50 N). The large operating torque degraded adjustment precision, making fine positioning difficult.
The ballscrew uses lead ph = 5 mm with a handwheel diameter D = 60 mm. Travel per revolution is 5 mm; the ratio of handwheel rim speed to lift speed is 60 × π / 5 ≈ 37.7, meaning the handwheel must turn 37.7 revolutions to move the table 5 mm. Ignoring friction, operating torque T = F × ph / (2π × η) = 1000 × 0.005 / (6.28 × 0.9) = 0.88 Nm, and handwheel tangential force F_h = T / (D/2) = 0.88 / 0.03 = 29.3 N; but with friction, seal resistance and poor lubrication the actual force reaches 120 N. A manual mechanism's lead should not be too large or too small — here 5 mm is too small.
① Manual adjustment force should be ≤50 N (ergonomic standard)
② Lead selection: for manual operation the recommended lead is 10~20 mm
③ Re-select lead ph = 20 mm: 20 mm travel per handwheel revolution, operating force drops to about 30 N
④ Or use a worm-gear reduction (self-locking + force-saving, but lower efficiency needs compensation)
⑤ Optimize lubrication: use low-viscosity oil (reduces friction 30%)
⑥ Increase handwheel diameter to 80~100 mm to further reduce force
FT_11 Ball Screw Selection