E41-073 · Screw Selection · Heavy Horizontal Lathe Z Axis · ★★★★
During a rapid traverse of the lathe Z axis the screw nut suddenly came loose and the tool carriage ran out of control into the headstock. Inspection found all four M10 socket-head bolts connecting the nut flange broken at the root, with fatigue-fracture characteristics on the fracture faces.
The nut flange is connected to the slide by four M10×35 (grade 8.8) bolts with a preload torque of 45 Nm. In actual cutting the Z-axis axial force is about F_a=8000 N (turning Ø200 mm, feed 0.5 mm/r), so each of the four bolts averages 2000 N. But a ~0.05 mm installation gap exists between the slide and the nut seat, generating impact load when the gap closes. In reciprocating cutting the impact factor K_d≈2.5, so each bolt actually sees a peak load F_peak=2000×2.5=5000 N. The proof load of an M10 (grade 8.8) bolt is about 28 kN and its fatigue limit about 12 kN (10⁷ cycles); 5000 N is within the fatigue limit, but root stress concentration K_t≈3.5 (sharp thread root) gives an equivalent fatigue stress amplitude σ=K_t×F/A_s=3.5×5000/58=302 MPa — far exceeding the bolt fatigue limit (about 100 MPa @10⁷).
① Bolt fatigue check: σ_a=K_t×ΔF/(2×A_s)≤[σ_a]
② Use grade 10.9 bolts (fatigue limit increased by 30%)
③ Increase bolt diameter: M10→M12 (cross-section +44%, stress −30%)
④ Eliminate installation gap: fit locating pins between nut seat and slide (Φ10h7 interference fit)
⑤ Bolt preload check: F_pre=0.7×σ_s×A_s=0.7×800×58=32.5 kN (safe)
⑥ Increase bolt count: 4→6