E41-179 · Screw Selection · Automated-Line Multi-Axis Screw Lubrication · ★★★
The temperature of the centralized-lubrication-fed screw nut rose from 40℃ to 85℃ after 2 hours of operation; teardown revealed the lubricant line was clogged with debris at a branch, so the nut ran dry.
The centralized lubrication system feeds four screw nuts through Φ4mm copper tubes via a tee distributor. The grease contained a small amount of debris (metal chips about 50μm) that accumulated at the tee distributor. Because the four branches differ in length (1.5~3m), the lowest-resistance branch received most of the grease, while the highest-resistance branch (longest line plus most elbows) got only 10% of its design oil volume. The starved nut ran under boundary lubrication; its friction coefficient rose from 0.004 to 0.02 and its heat generation increased fivefold. Temperature climbed from 40℃ to 85℃, and at 85℃ the grease oxidized and failed much faster, creating a vicious cycle. After about 200 hours the nut raceway developed adhesive wear (galling), which is irreparable.
① Each branch of the centralized lubrication system should have a flow-control valve (to ensure even oil distribution)\n② Grease filtration rating ≥25μm (to prevent debris clogging)\n③ Keep branch line lengths as equal as possible (length difference ≤20%)\n④ Fit each nut with a lubrication-status indicator (to observe the oil flow)\n⑤ Or use independent lubrication (each nut oiled separately, with no mutual influence)