E41-340 · Screw Selection · Machining Center Bearing-Housing Bore Wear · ★★★★
The machining center X-axis positioning accuracy degraded from ±0.003mm to ±0.008mm; inspection found about 0.02mm wear on the screw fixed-end bearing-housing bore, with the bearing outer ring fretting inside the bore.
The fixed-end bearing uses a paired angular-contact ball bearing (7206C/DB) mounted in the housing bore, with bore tolerance Φ62H7 (+0.030/0). After 3 years of use (about 2×10⁶ reciprocations), the bearing outer ring fretted in the bore, wearing the bore about 0.02mm. The fit changed from the original transition fit (clearance 0~0.030mm) to a clearance fit (about 0.02~0.05mm). With the outer ring no longer fully fixed in the bore, the screw's axial location shifted slightly. The cause of the accuracy loss: outer-ring fretting dropped the fixed-end axial stiffness K from 500N/μm to about 300N/μm, so under a 3000N cutting force the axial displacement δ=F/K=3000/300=10μm, and because the displacement varies with cutting force (non-constant) the machining dimension fluctuated by ±0.005mm.
① Repair a worn bearing-housing bore: insert a bushing → re-bore to standard size\n② Bore size control: Φ62H7 (+0.030/0), roundness ≤0.005mm\n③ At bearing installation, coat the outer ring with bearing retaining compound (Loctite 641) to fill the clearance and prevent fretting\n④ Or use a flanged-outer-ring bearing unit (no fretting problem)\n⑤ Keep a bore-size record (inspect once a year; repair when wear >0.01mm)
FT_11 Ball Screw Selection