E41-345 · Screw Selection · Drying-Equipment Screw Bearing · ★★★★
The fixed-end bearing of a drying-equipment feed screw ran in a 120℃ environment; after 3 months it seized, the bearing grease was coke-like, and the bearing raceway was severely worn.
The drying equipment interior is 120℃, and the screw bearing housing is mounted in this environment. The bearing used lithium grease (service temperature -20~120℃), near its upper limit at 120℃. The bearing operating temperature = ambient 120℃ + friction rise 15℃ = 135℃, exceeding the lithium grease limit by 15℃. At 135℃ the lithium grease base oil evaporated rapidly (about 5%/month), the thickener (lithium soap) decomposed, and the grease essentially carbonized and failed within 3 months. The bearing ran starved of grease; its friction coefficient rose from 0.004 to 0.02, heat generation increased 5× → temperature rose to 150℃ → the bearing steel tempered and softened (hardness dropped from HRC62 to HRC50) → the raceway plastically deformed → the bearing seized.
① In high-temperature environments (>100℃), use a PFPE (perfluoropolyether) grease (temperature rating 250℃)\n② PFPE grease life at 135℃ ≥5000h (vs. ≤500h for lithium grease)\n③ Or use a high-temperature bearing (heat-resistant cage + PTFE liner, no grease needed)\n④ Add thermal insulation to the bearing housing (10mm ceramic fiber, cuts temperature ~30℃)\n⑤ Add cooling-air blow (compressed-air purge on the housing, drop ~20~30℃)
FT_11 Ball Screw Selection