E41-348 · Screw Selection · Boring Machine Screw Parallelism Shim Loosening · ★★★★
Over 6 months the boring machine X-axis screw-to-guideway parallelism drifted from 0.01mm/1000mm to 0.05mm/1000mm, exceeding the machining accuracy limit.
The screw bearing-housing adjustment shim (stainless steel, 0.5mm thick) was not fixed (held only by friction). Under vibration from screw operation (acceleration about 2m/s²) the shim gradually slid outward. Originally centered under the housing, after 6 months it had moved out about 3mm, leaving one side of the housing unsupported. The housing tilted (tilt angle θ = shim shift / housing width = 3/80 = 0.0375rad ≈ 2.15°), and the screw centerline skewed accordingly. After skewing, the vertical screw-to-guideway parallelism deviation grew to 0.05mm/1000mm. The skew produced an extra radial force, accelerating nut wear.
① The adjustment shim must be anti-slip treated: apply a friction enhancer (Loctite 7649)\n② Provide a locating pin between shim and housing (interference fit, prevents sliding)\n③ Or use an adjustable wedge (precise adjustment via set screw, no sliding risk)\n④ Shim area should be ≥ the housing base area (for uniform contact pressure)\n⑤ Check parallelism quarterly after installation (adjust promptly if deviation found)
FT_11 Ball Screw Selection