E41-352 · Screw Selection · Dust-Environment Screw Explosion-Proofing · ★★★★★
The screw drive system in a flour-mill packaging workshop produced sparks during operation, igniting flour dust (dust-cloud concentration 50g/m³, minimum ignition energy 10mJ).
A well-lubricated screw-nut assembly produces no sparks (an oil film separates the balls from the raceway), but when starved of grease or in metal-to-metal contact, friction between balls and raceway can generate frictional sparks. The spark energy from GCr15 balls (HRC62) rubbing the raceway (GCr15, HRC60~62) is about 0.5~2mJ. Flour-dust minimum ignition energy (MIE) is 10~50mJ, so a single friction spark (≤2mJ) is below the MIE and safe. But static accumulated in the dust environment can also discharge (human-body static discharge energy about 1~20mJ), and the screw metal parts can become static accumulators, increasing ignition risk. The explosion-protection code (GB 50058-2014) requires equipment in dust Zone 21 (where dust may appear) to meet explosion-proof requirements.
① In dust environments use an explosion-proof screw (bronze-alloy balls + anti-static grease)\n② Reliably ground the screw system (grounding resistance ≤4Ω, to prevent static accumulation)\n③ Use anti-static grease (with conductive additive, reducing resistivity ≤10⁹Ω·m)\n④ Fit the screw with a guard (sealed, to keep dust out)\n⑤ Control dust concentration below 25% of the lower explosive limit (ventilation/dedusting)
FT_11 Ball Screw Selection