E41-353 · Screw Selection · Heavy Horizontal Lathe Screw Keyway Fracture · ★★★★
A heavy horizontal lathe screw (Φ60mm) fractured in torsion at the shaft-end keyway; the keyway depth was 8mm (13.3% of the 60mm shaft), and the effective shaft section was only 72%.
The screw shaft-end keyway (flat key 18×11mm) has depth t=11mm (shaft 60mm); the effective section diameter d_eff=d-t=60-11=49mm. The torsional section modulus W_t=π×d_eff³/16=3.14×49³/16≈23000mm³. Transmitted torque T=3000Nm gives torsional stress τ=T/W_t=3000000/23000≈130MPa. For 40Cr (quenched and tempered) the torsional strength τ_b≈0.6×σ_b=0.6×980=588MPa, static safety factor 4.5. But the keyway-bottom fillet R=0.5mm gives Kt≈2.5, so peak stress τ_peak=Kt×τ=2.5×130=325MPa — about 55% of the 588MPa torsional strength. Under heavy impact (startup impact T_peak=2×T_nom=6000Nm), τ_peak_impact=2×325=650MPa > 588MPa, so the keyway root plastically deforms in one event → fatigue fracture after about 500 impacts.
① Keyway-depth standard: t≤0.3×d (here 11/60=0.183 → OK, but impact duty should be more conservative)\n② Keyway-bottom fillet R≥0.8mm (Kt from 2.5 to 1.8)\n③ Under impact duty, drop the key connection; use a spline or shrink disc\n④ Keyway surface rolling strengthening (fatigue strength up 30%)\n⑤ Or switch to a hollow shaft (spline on the inner wall, better strength)
FT_11 Ball Screw Selection